Village QVI30 Owner's Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Quadra-Fire • QVI-30FB • 2020-900 Rev. H • 9/07
14
Figure 4.
This option shows both exhaust and inlet
air vent pipes attached to the adaptor.
WARNING: THE EXHAUST VENT PIPE MUST
ONLY BE CONNECTED TO THE EXHAUST
STARTING COLLAR OF THE UNIT AND THE
CENTER COLLAR OF THE TERMINATION CAP.
A 3 FOOT SECTION OF STAINLESS STEEL
FLEXIBLE LINER MUST BE ATTACHED
DIRECTLY TO THE EXHAUST COLLAR ON
COLLAR SLIDE PLATE.
!
THE INLET AIR PIPE MUST ONLY BE
CONNECTED TO THE INLET AIR COLLAR OF
THE UNIT AND EITHER ATTACHED TO THE
INLET AIR COLLAR OF THE TERMINATION CAP
OR TERMINATED IN THE CHIMNEY.
!
!
TERMINATION
CAP
EXHAUST
VENT PIPE
V
= 14 FT. MINIMUM
50FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
SEAL DAMPER
AREA
COLLAR ATTACHMENT
BRACKET
EXHAUST COLLAR
INLET AIR COLLAR
INLET AIR
VENT PIPE
FLASHING
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 24 25

Comments to this Manuals

No comments