Village QV36B Specifications Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06
Figure 5. Framing Dimensions
Step 2. Framing the Fireplace
Fireplace framing can be built before or after the fireplace
is set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
Framing should be constructed
of 2 X 4 lumber or heavier.
The framing headers may rest
on the fireplace stand-offs.
The center of the framing hole is one
(1) inch (25.4mm) above the center of
the horizontal vent pipe.
Model A B C D E
QV36B 42 38 1/4” 16 1/4” 41 27 7/8”
QV32B 37 33 16 1/4” 36 1/2” 24 3/8”
WARNING:
To ensure proper clearances
the front framing header must
be installed on its narrow edge
and to the front of the frame.
A
B
C
WALL STUD
NON-COMBUSTIBLE ZON
IS DEFINED BY 3” ABOVE THE
ELBOW FOR THE ENTIRE
WIDTH AND DEPTH (BEHIND THE
FRONT HEADER) OF THE FIREBOX.
3 1/2”
3
Î
VENT
FRAMING
HOLE
E
D
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 43 44

Comments to this Manuals

No comments